9.a - BS5308 Control and Instrumentation Cable Non-Armoured with Collective Screen - Part 1, Type 1 Overall Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables - Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation, Blue or Black to BS5308 Part Type 1. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.

9.b - BS5308 Control and Instrumentation Cable Non-Armoured with Individual and Collective Screens - Part 1, Type 1 Individually Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, and IEC 60332-1.

9.c - BS5308 Control and Instrumentation Cable Armoured with Collective Screen - Part 1, Type 2 Overall Screened 0.5mm to 2.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and  IEC 332-3C.

9.d - BS5308 Control and Instrumentation Cable Armoured with Individual and Collective Screen - Part 1, Type 2 Individually Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium /mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, polyethylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation . Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.

9.e - BS5308 Control and Instrumentation Cable Non-Armoured with Collective Screen - Part 2, Type 1, Overall Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminum/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black to BS5308 Part 2 Type 1. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. 

9.f - BS5308 Control and Instrumentation Cable Non-Armoured with Individual and Collective Screens - Part 2, Type 1 Individually Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, PVC insulated , laid up to form pairs, each pair individually aluminium /mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.

9.g - BS5308 Control and Instrumentation Cable Armoured with Collective Screen - Part 2, Type 2 Overall Screened 0.5mm to 2.5mm

Instrumentation & Thermocouple Cables - Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, Polytheylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.

9.h - BS5308 Control and Instrumentation Cable Armoured with Individual and Collective Screen - Part 2, Type 2 Individually Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen PVC bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.

9.i - BS5308 Control and Instrumentation Cable Non Armoured with Collective Screen - Part 1, Type 1 LSZH, Overall Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables - Plain annealed flexible copper conductors,XLPE insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) sheath, Blue or Black, to BS5308 Part 1, Type 1 LSZH.

9.j - BS5308 Control and Instrumentation Cable Non-Armoured with Individual and Collective Screens - Part 1, Type 1 LSZH Individually Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar tape screened. Complete with 0.5mm2 drain wire, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke xero halogen (LSZH) outer sheath, Black or Blue, generally to BS5308 Part 1, Type 1 LSZH.

9.k - BS5308 Control and Instrumentation Cable Armoured with Collective Screen - Part 1, Type 2 LSZH Overall Screened 0.5mm to 2.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium /mylar foil tape screen, complete with 0.5mm2 drain wire, low smoke zero halogen bedding (LSZH), galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Black or Blue, generally to BS5308 Part 1, Type 2 LSZH.

9.l - BS5308 Control and Instrumentation Cable Armoured with Individual and Collective Screen - Part 1, Type 2 LSZH Individually Screened 0.5mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Blue or Black, generally to BS5308.

9.m - BS5308 Control and Instrumentation Cable Lead Sheathed Armoured with Collective Screen - Part 1, Type 3 Overall Screened 0.75mm to 1.5mm

Instrumentation & Thermocouple Cables - Plain annealed copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium /mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. 

9.n - BS5308 Control and Instrumentation Cable Lead Sheathed Armoured with Individual and Collective Screens - Part 1, Type 3 Individually Screened 0.75mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminum/mylar tape screen, complete with 0.5mm2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.

9.o - BS5308 Control and Instrumentation Cable Lead Sheathed Armoured with Collective Screen - Part 2, Type 3 Overall Screened 0.75mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, PVC insulated laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil, tape screen, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black.

9.p - BS5308 Control and Instrumentation Cable Lead Sheathed Armoured with Individual and Collective Screens - Part 2, Type 3 Individually Screened 0.75mm to 1.5mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.

9.q - BSC Type134 CES20 - Instrumentation Cable to British Steel Specification 0.75mm

Instrumentation & Thermocouple Cables - Plain annealed flexible copper inductors, PVC bedding, tinned annealed copper wire braid screen, PVC bedding, galvanised steel wire armour, PVC outer sheath. Grey. 300/500 volts grade to British Steel specification CES 20 part 4, Type 134. Flame propagation to BS EN 50265 and IEC 60332-1.

9.r - BSC Type143 CES20 - Instrumentation Cable to British Steel Specification 0.75mm

Instrumentation & Thermocouple Cables  - Tinned annealed flexible copper conductors, PVC insulated and laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Orange. 300/500 volts grade. Type 143. Flame propagation to BS EN 50265 and IEC 60332-1.

9.s - Thermocouple - PVC Insulated Non-Armoured Collective Screened Extension and Compensating Cable 0.75mm

Instrumentation & Thermocouple Cables - Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm2 drain wire, PVC outer sheath.Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1.

9.t - Thermocouple - PVC Insulated Armoured Collective Screened Extension and Compensation Cable 0.75mm

Instrumentation & Thermocouple Cables  - Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1.