Railway Points Heating Cable

Point_Heater_Cables

Cable Specification: Point Heater Cable available in sizes 1.5mm to 16mm and manufactured to British Standard BS6360. The cable features flexible tinned copper conductor to BS6360, EPR insulation type GP4 to BS7655, black PCP type EM2 sheath to BS7655. Manufactured to Network Rail specification NR/SP/ELP/40045 (Formerly R/E/PS/40045).

  • Technical
  • Products
  • Downloads

Railway Points Heating Cable

Purpose: The Point Heater cables are specifically designed for power distribution in points heating systems. They are heavy duty cables which offer protection from abrasion and mechanical damage whilst maintaining the flexibility for flexibility for ease of installation. The British Standard cable features flexible tinned copper conductors, EPR type GP4 insulation and a black PCP type EM2 sheath.

StandardsBS6360, BS7655, NR/SP/ELP/40045 (Formerly R/E/PS/40045).

Conductor: Flexible Tinned Copper Conductor

Insulation: EPR Type GP4

Sheath: PCP Type EM2

Sheath Colour: Black

Temperature Rating: Temperature limits: -30°C to +70°C

Manufactured to Network Rail specification NR/SP/ELP/40045 (formerly R/E/PS/40045)

For more information please consult a member of the Cleveland Cable Sales Team.

Core Identification

4 core - Yellow Yellow    Yellow Yellow   Blue Blue   Blue Blue  

8 core - Yellow Yellow   Yellow Yellow   Blue Blue   Blue Blue   Brown Brown   Brown Brown   Black Black   Black Black  

CCC_Code Rail Code Conductor Size(mm2) Stranding(mm) No of Cores Weight(Kg/Km) Overall Diameter(mm) Gland Size
3184PH1/5
4X1.5 EPR,PCP, POINT HEATER CABLE 006/150002
Rail Code: 6/150002 Conductor Size(mm2): 1.5 Stranding(mm): 30/0.25 No of Cores: 4 Weight(Kg/Km): 220 Overall Diameter(mm): 14.32 Gland Size: 25
4X1.5 EPR,PCP, POINT HEATER CABLE 006/150002
3188PH1/5
8X1.5 EPR,PCP POINT HEATER CABLE
Rail Code: 6/153002 Conductor Size(mm2): 1.5 Stranding(mm): 30/0.25 No of Cores: 8 Weight(Kg/Km): 460 Overall Diameter(mm): 18.44 Gland Size: 25
8X1.5 EPR,PCP POINT HEATER CABLE
3188PH2/5
8X2.5 EPR PCP POINT HEATER CABLE
Rail Code: Conductor Size(mm2): 2.5 Stranding(mm): 50/0.25 No of Cores: 8 Weight(Kg/Km): 510 Overall Diameter(mm): 23.36 Gland Size: 32
8X2.5 EPR PCP POINT HEATER CABLE
6388PH4
8X4 EPR,PCP POINT HEATER CABLE 006/153103
Rail Code: 6/153103 Conductor Size(mm2): 4 Stranding(mm): 56/0.30 No of Cores: 8 Weight(Kg/Km): 830 Overall Diameter(mm): 23.6 Gland Size: 32
8X4 EPR,PCP POINT HEATER CABLE 006/153103
6388PH6
8X6 EPR, PCP POINT HEATER CABLE
Rail Code: Conductor Size(mm2): 6 Stranding(mm): 84/0.30 No of Cores: 8 Weight(Kg/Km): 1040 Overall Diameter(mm): 25.6 Gland Size: 32
8X6 EPR, PCP POINT HEATER CABLE
6388PH10
8X10 EPR PCP POINT HEATER CABLE
Rail Code: Conductor Size(mm2): 10 Stranding(mm): 75/0.40 No of Cores: 8 Weight(Kg/Km): 1799 Overall Diameter(mm): 31.7 Gland Size: 40
8X10 EPR PCP POINT HEATER CABLE
6388PH16
8X16 EPR PCP POINT HEATER CABLE
Rail Code: Conductor Size(mm2): 16 Stranding(mm): 118/0.40 No of Cores: 8 Weight(Kg/Km): 2480 Overall Diameter(mm): 36.2 Gland Size: 50S
8X16 EPR PCP POINT HEATER CABLE