BS 5467 SWA EEMUA133 Underground Cable 3kV - 25 to 300mm

EEMUA_Power-3300V

Application Overview: EEMUA 133 cables are generally used for installation underground in the moist areas in the oil, gas and petrochemical industries. The steel wire armour gives good mechanical protection and the lead cover provides good resistance to aromatic hydrocarbons. EEMUA stands for the Engineering Equipment & Materials Users Association. More details can be found within the technical information section below.

  • Technical
  • Products
  • Downloads

BS 5467 SWA EEMUA133 Underground Cable 3kV - 25 to 300mm

Standards

Generally to BS5467

EEMUA 133 (formerly OCMA 4B). 

BS EN 60332-1 (IEC 60332-1), 

BS EN 50266-2-2 (IEC 60332-3-22 category A) 

BS EN 50266-2-4 (IEC 60332-3-24 category C).

Construction

Conductor: Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360)

Insulation: Cross Link Polyethylene (XLPE)

Bedding: Polyvinyl Chloride (PVC)

Inner Sheath: Lead Sheathed

Bedding: Polyvinyl Chloride (PVC)

Armour: Steel Wire Armour (SWA)

Sheath: Polyvinyl Chloride PVC

Characteristics

Voltage Rating: 1900V to 3300V

Temperature Limits: -15°C to +90°C 

Minimum Bending Radius: As per cable manufacturer datasheet

For more information please consult a member of the Cleveland Cable Sales Team.

Core Identification

3 core - Brown Brown   Black Black   Grey Grey  

CCC_Code Conductor Size (mm2) Stranding(mm) No Of Cores Weight(Kg/Km) Overall Diameter(mm) Gland Size Nylon Cleat Size
EEMUA3X25/3
3X25MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 25 Stranding(mm): 7/2.14 No Of Cores: 3 Weight(Kg/Km): 3400 Overall Diameter(mm): 32.5 Gland Size: 32 Nylon Cleat Size: 1.4
3X25MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X35/3
3X35MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 35 Stranding(mm): 19/1.53 No Of Cores: 3 Weight(Kg/Km): 3560 Overall Diameter(mm): 38.4 Gland Size: 40 Nylon Cleat Size: 1.6
3X35MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X50/3
3X50MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 50 Stranding(mm): 19/1.78 No Of Cores: 3 Weight(Kg/Km): 4520 Overall Diameter(mm): 38.1 Gland Size: 40 Nylon Cleat Size: 1.6
3X50MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X70/3
3X70MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 70 Stranding(mm): 19/2.14 No Of Cores: 3 Weight(Kg/Km): 5550 Overall Diameter(mm): 41.4 Gland Size: 50S Nylon Cleat Size: 1.8
3X70MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X95/3
3X95MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 95 Stranding(mm): 19/2.52 No Of Cores: 3 Weight(Kg/Km): 6770 Overall Diameter(mm): 45.0 Gland Size: 50S Nylon Cleat Size: 2.0
3X95MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X120/3
3X120MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 120 Stranding(mm): 37/2.03 No Of Cores: 3 Weight(Kg/Km): 8390 Overall Diameter(mm): 49.4 Gland Size: 50 Nylon Cleat Size: 2.0
3X120MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X150/3
3X150MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 150 Stranding(mm): 37/2.25 No Of Cores: 3 Weight(Kg/Km): 9630 Overall Diameter(mm): 52.3 Gland Size: 50 Nylon Cleat Size: TC9
3X150MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X185/3
3X185MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 185 Stranding(mm): 37/2.52 No Of Cores: 3 Weight(Kg/Km): 11270 Overall Diameter(mm): 55.8 Gland Size: 63S Nylon Cleat Size: TC9
3X185MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X240/3
3X240MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 240 Stranding(mm): 61/2.25 No Of Cores: 3 Weight(Kg/Km): 13720 Overall Diameter(mm): 60.9 Gland Size: 63 Nylon Cleat Size: TC10
3X240MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
EEMUA3X300/3
3X300MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA
Conductor Size (mm2): 300 Stranding(mm): 61/2.52 No Of Cores: 3 Weight(Kg/Km): 16380 Overall Diameter(mm): 65.3 Gland Size: 75S Nylon Cleat Size: TC11
3X300MM XLPE,LC,PVC,SWA,PVC 3.3KV EEMUA

3.3KV EEMUA Datasheet
Last modified 26/04/2019 10:40:41


Bespoke Cable Request