BS4937 Compensating & Thermocouple Cable Non Armoured - 0.75mm²
 
                            Description
Generally used for interconnection between thermocouple probes and control instrumentation. They are used in industries such as power generation, oil, gas and pharmaceutical and are used in everyday appliances such as furnaces and ovens.
Key Features
- 
                                                Voltage Rating 250 Volts
- 
                                                Minimum Bending Radius 10 x Overall Diameter
- 
                                                Flame Retardancy BS EN/IEC 60332-1
- 
                                                Temperature Limits Temperature Range: -30°C To +105°C
Construction
- 
                                            Conductor: Class 2 stranded copper
- 
                                            Insulation: Polyvinyl Chloride (PVC)
- 
                                            Screen: Collective Aluminium/mylar tape with 0.5mm drain wire
- 
                                            Overall Tape Screen: Polyester tape wrapping
- 
                                            Bedding: Polyvinyl Chloride (PVC)
- 
                                            Outer Sheath: Polyvinyl Chloride (PVC)
- 
                                            Sheath Colour: as per Colour Code Chart
Standards
- 
                                                BS EN/IEC 60584-3
- 
                                                BS EN/IEC 60228
- 
                                                BS EN/IEC 60332-1
Core Colours
See PDF datasheet for Colour Chart