ENATS 09-6 Telecommunications Cable - SCR, SWA - 0.50mm

ENATS 09-6 Telecommunications Cable - SCR, SWA - 0.50mm

Description

Telecommunication cable is predominantly used in electrical instrumentation and communications. The cable is manufactured to specification ENATS 09-6 Section 4.5. (Electrical National Association and Technical specification). ENATS is the governing body who cover utilities specification cables.

Key Features
  • Flame Retardancy
    Flame Retardancy BS4066 PT1 & IEC 332 PT1
  • Temperature Limits
    Temperature Limits Fixed -30°C to +70°C
Construction
  • Conductor: Solid Plain Annealed Copper Conductors
  • Insulation: Polyvinyl Chloride (PVC)
  • Bedding: Polyvinyl Chloride (PVC)
  • Screen: Collective Aluminium/mylar tape with 0.5mm drain wire
  • Armour: Galvanised Steel Wire Armour (GSWA)
  • Sheath: PVC (Polyvinyl Chloride)
  • Sheath Colour: Black

Core Colours

**All two pair cables are in quad formation and colour coded in rotation.
White Red Blue Orange

For 30 pair cables the formation will be - 3 x 10 pair units numbered - 1, 2 & 3
For 40 pair cables the formation will be - 2 x 20 pair units numbered - 1 & 2
For 50 pair cables the formation will be - 5 x 10 pair units numbered - 1, 2 3, 4 & 5
For 100 pair cables the formation will be - 5 x 20 pair units numbered - 1, 2, 3, 4 & 5