Railway Points Heater Cable - EPR, PCP - 1.5mm² to 16mm²
 
                            Description
Point Heater Cables meetNetworkRail standardsandare specifically designed forpowering point heatingsystemsto protectthemduringcoldweatherandtheassociatedlowtemperatures. They are a heavy duty flexible cable which still offer good protection fromabrasion and mechanical damage whilst not being armoured.
Manufactured to Network Rail specification NR/SP/ELP/40045 (formerly R/E/PS/40045)
Key Features
- 
                                                Voltage Rating 300/500 Volts
 Dependent Upon Network Rail Application
- 
                                                Minimum Bending Radius 7.5 x overall diameter
- 
                                                Temperature Limits Fixed -30°C to +70°C
Construction
- 
                                            Conductor: Class 5 tinned copper
- 
                                            Insulation: Ethylene Propylene Rubber (EPR) Type GP4
- 
                                            Outer Sheath: Polychloroprene (PCP) Type EM2
- 
                                            Sheath Colour: Black
Standards
- 
                                                Network Rail Specification NR/L2/ELP/40045
- 
                                                BS EN/IEC 60228
- 
                                                BS EN 50363
Core Colours
4 core
Yellow Yellow Blue Blue
8 core
Yellow Yellow Blue Blue Brown Brown Black Black