Railway Signalling Cable - Type C, D & E - LSZH, EPR, PCP - 0.75mm to 35mm

Description
Signalling cable especially manufactured for Network Rail against their specification NR/PS/SIG/00005, formerly RT/E/PS/00005.
Key Features
-
Installation Guidelines Should not be installed at temperatures below 0°C or above +60°C
-
Voltage Rating 650/1100 Volts
-
Minimum Bending Radius As Per Manufacturers Datasheet
Construction
-
Conductor: Flexible tinned or stranded copper conductor to BS EN 60228 (previously BS 6360)
-
Insulation: EPR (Ethylene Propylene Rubber)
-
Sheath: Type C1 & C2: Heavy duty PCP RS2 Type D1 & D2 Low Smoke Zero Halogen (LSZH)Type E1 & E2 Low Smoke Zero Halogen (LSZH)
-
Sheath Colour: Black
Standards
-
Conductor to BS EN 60228 (previously BS 6360), EPR Insulation to BS7655-3-2, Network Rail Specification NR/PS/SIG/00005
Core Colours
1-48 Black cores with White numbers